Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Sato, Rina; Sanada, Yukihisa; Yoshimura, Kazuya; Nakayama, Mariko*
JAEA-Review 2022-055, 42 Pages, 2023/01
The evacuation order zones established after the accident at the Tokyo Electric Power Company's Fukushima Daiichi Nuclear Power Station have been reorganized according to the decrease in ambient dose equivalent rates and the decontamination progress. It has been decided to decontaminate the difficult-to-return zones and lift the evacuation order depending on the evacuee's intention of returning to the areas over the course of the 2020s. In order to consider the future of individual exposure dose assessment for residents for lifting of the evacuation orders, the methods and characteristics of the assessment that have been conducted after the accident using personal dosimeter measurements and simulations were systematically reviewed. This report summarized the results of the review.
Sato, Rina; Yoshimura, Kazuya; Sanada, Yukihisa; Sato, Tetsuro*
Journal of Radiation Protection and Research, 47(2), p.77 - 85, 2022/06
After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. This study validates the model's accuracy by comparing the estimated effective doses with the measured personal dose equivalents. The personal dose equivalents and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. The estimated effective doses correlated significantly with the personal dose equivalents, demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose relative to personal dose equivalent indoors could be because the conversion factor from ambient dose equivalent to effective dose did not reflect the actual environment.
Sato, Tetsuro*; Ando, Masaki; Sato, Masako*; Saito, Kimiaki
Journal of Environmental Radioactivity, 210, p.105973_1 - 105973_7, 2019/12
Times Cited Count:9 Percentile:36.49(Environmental Sciences)A method was devised for estimation of external doses of Fukushima residents expected to return to their homes after evacuation orders are lifted. 211 residents expected to return to six towns and villages were surveyed in FY 2014, FY 2015, and FY2016. Interviewing returning residents about their expected life patterns after returning, air dose rate were measured along the reported personal trails representing their patterns of movement in daily life. Excluding 15 residents from whose homes we were unable to take air dose rate measurements, the maximum external effective dose and the average external effective dose were estimated respectively as 4.9 mSv/y and 0.86 mSv/y. Although the mean values and dispersion of external effective doses differ depending on the evacuation level, for 93.3% of all residents, the estimated external effective doses were less than 2 mSv/y. The average exposure dose at home accounts for 66.8% of the annual exposure dose.
Endo, Akira
Radiation Protection Dosimetry, 175(3), p.378 - 387, 2017/07
Times Cited Count:11 Percentile:72.62(Environmental Sciences)The International Commission on Radiation Units and Measurements (ICRU) has been discussing to propose a new system of the operational quantities for external radiations based on protection quantities. The aim of this study is to provide a set of conversion coefficients for use in defining personal dose equivalent for individual monitoring. Fluence-to-effective dose conversion coefficients have been calculated for photons, neutrons, electrons, positrons, protons, muons, pions and helium ions for various incident angles of radiations. The data sets comprise effective dose conversion coefficients for incident angles of radiations from 0 to 90 in steps of 15 and at 180. Conversion coefficients for rotational, isotropic, superior hemisphere semi-isotropic and inferior hemisphere semi-isotropic irradiations are also included. The conversion coefficients are used to define the operational quantity personal dose equivalent which is being considered by ICRU and utilized for the design and calibration of dosemeters.
Saito, Kimiaki; Kurihara, Osamu*; Matsuda, Norihiro; Takahara, Shogo; Sato, Tetsuro*
Radioisotopes, 65(2), p.93 - 112, 2016/02
Late information is introduced on dose evaluation due to external exposures which employ an important role in the exposures due to the Fukushima accident. First, merits and demerits of the currently used two methods, that is the estimation based air dose rates and the measurements using personal dosimeters, are discussed indicating some basic data after a fundamental concept of external dose evaluation is provided. Next, main activities are summarized on external dose measurements and evaluations after the accident. Finally, a new trial on dose evaluation in introduced.
Ito, Masashi; Shiraishi, Akemi; Murakami, Hiroyuki
JAERI-Tech 2001-048, 20 Pages, 2001/07
In Japan Atomic Energy Research Institute, a new type radiophotoluminescent(RPL) glass dosimeter is recently adopted replaced film badge for external personal monitoring. Some fundamental characteristics of this dosimeter, such as dose dependence linearity, energy dependence, dose evaluation accuracy against mixed irradiation condition,fading, etc.,were examined at the Facility of Radiation Standard(FRS),JAERI. The results have proved that the RPL glass dosimeter has sufficient characteristics in practical use as a personal dosimeter for all of the items examined.
Ikezawa, Yoshio
Nihon Genshiryoku Gakkai-Shi, 33(5), p.439 - 440, 1991/05
no abstracts in English
Sato, Rina; Yoshimura, Kazuya; Sanada, Yukihisa; Sato, Tetsuro*; Takagi, Marie*
no journal, ,
no abstracts in English
Sato, Rina; Yoshimura, Kazuya; Sanada, Yukihisa; Sato, Tetsuro*; Takagi, Marie*
no journal, ,
no abstracts in English